Yog manufactures Thermocouples, Resistance Temperature Detectors, Temperature Transducers, wide range of Digital Temperature Indicator/Controllers, Scanners, Recorders, Transmitters to monitor and control various industrial processes.
|
| |
|
|
Thermocouples |
'K' (Chromel-Alumel).
'J' (Iron-Constantan).
'T' (Copper- Constantan).
'E' (Chromel-Constantan). 'R' (Pt-Pt-13%-Rh).
'S' (Pt-Pt-10%Rh). 'B' (Pt-13%-Rh-Pt-6%Rh) in Simplex, Duplex and Triplex
|
|
| |
Resistance Temperature Detectors |
Pt-50, Pt-100. Pt-500, Pt-1000, Ni-100, Cu-200 in Simplex, Duplex and Triplex.
Types of Insulation : Ceramic insulation and Mineral insulation.
Types of Junction : Grounded, Ungrounded (Isolated)
Types of Sheath : Mild steel, SS 304, SS 316, SS 446, SS 310, Inconel 600. Inconel 800, Titanium, Cast Iron. Nickel, Brass, Copper, Aluminium, Ceramic (610), Recrystised Alumina (KER 710). etc.
Dimensions : Diameter of sheath from 0.08 mm up to 25.4 mm In case of Cast Iron Sheath 12 mm up to 50 mm or more. (In exceptional case diameter can be Increased).
Immersion length : As per the requirement or application/custom built.
Shapes & Sizes : As per the requirement or application. |
| |
|
| |
Temperature Controller |
Model A : YOG-062 Single Set
Model B : YOG-062/D Double Set |
|
Specifications
Input
RTD (Pt-100) Thermocouples (Fe-Con-'J'/Cr-Al 'K'/Pt. Pt. Rh. 10% 'S'/Pt. Pt. Rh 13% 'R' etc.)
Range
For RTD (Pt-100) - 1000C to 199.90C (Resolution 0.10C) or 00C to 5000C (Resolution 10C) For
Fe-Con 'J' - 00C to 6000C
Cr-Al 'K' - 00C to 12000C
Pt. Pt. Rh. 10% 'S' - 10000C to 16000C
Pt. Pt. Rh. 13% 'R' 10000C to 16000C
Indication : Seven Segment LED 3.5 Digit 1/2" size.
Accuracy of Indication : ±0.5% of FSD ± 1 Digit.
Control Accuracy : 10C to 20C Nominal (Can be adjusted)
Relay : Contact rating 5 Amps/230 Volt AC.
Operating Temperature 0C to 500C
Supply Voltage 230 VAC±10%
Size
A) 96 x 96 x 110 mm (WxHxD) one or two set point controller. Panel cut out : 92 x 92 mm.
B) 72 x 72 x 110 mm
(WxHxD) one set point Controller. Panel cut out : 68 x 68 mm. |
| |
|
| |
Temperature Indicator |
Model : YOG-026
|
Specifications
Input
RTD (pt-100) Thermocouples (Fe-Con- 'J'/Cr-Al 'K'/Pt. Pt. Rh. 10% 'S'/ Pt. Pt. Rh. 13% 'R' etc.)
Range
For RTD (Pt-100) - 1000C to 199.90C (Resolution 0.10C) or 00C to 5000C (Resolution 10C) For
Fe-Con 'J' - 00C to 6000C
Cr-Al 'K' - 00C to 12000C
Pt. Pt. Rh. 10% 'S' - 10000C to 16000C
Pt. Pt. Rh. 13% 'R' 10000C to 16000C |
Specifications
Input
RTD (pt-100) Thermocouples (Fe-Con- 'J'/Cr-Al 'K'/Pt. Pt. Rh. 10% 'S'/ Pt. Pt. Rh. 13% 'R' etc.)
Range
For RTD (Pt-100) - 1000C to 199.90C (Resolution 0.10C) or 00C to 5000C (Resolution 10C) For
Fe-Con 'J' - 00C to 6000C
Cr-Al 'K' - 00C to 12000C
Pt. Pt. Rh. 10% 'S' - 10000C to 16000C
Pt. Pt. Rh. 13% 'R' 10000C to 16000C
Indication : Seven Segment LED 3.5 Digit 1/2" size.
Accuracy of Indication : ±0.5% of full scale Deflection 1 Digit.
Operating Temperature 0C to 500C
Supply Voltage 230 VAC±10%
Size
A) 96 x 96 x 110 mm (W x H x D) Panel cut out : 92 x 92 mm.
B) 96 x 48 x 110 mm (W x H x D) for half DIN type indicator.. Panel cut out : 92 x 45 mm.
B) 72 x 72 x 110 mm
(W x H x D) Panel cut out : 68 x 68 mm. |
| |
|
| |
| Temperature Indicator Portable |
| Model : YOG-053 |
Specifications
Input : RTD (pt-100) Thermocouples (Fe-Con- 'J'/Cr-Al 'K'/Pt. Pt. Rh. 10% 'S'/ Pt. Pt. Rh. 13% 'R' etc.)
| |
|
|
Range
For RTD (Pt-100) - 1000C to 199.90C (Resolution 0.10C) or 00C to 5000C (Resolution 10C) For
Fe-Con 'J' - 00C to 6000C
Cr-Al 'K' - 00C to 12000C
Pt. Pt. Rh. 10% 'S' - 10000C to 16000C
Pt. Pt. Rh. 13% 'R' 10000C to 16000C
Indication : Seven Segment LCD 3.5 Digit 1/2" size.
Accuracy of Indication : ±0.5% of full scale Deflection ±1 Digit.
Operating Temperature 0C to 500C
Supply Voltage 9V Battery
Input with RF/3Pin/Omga Connector
Press to Hold facility available as per requirement |
|
| |
|
|
Temperature Transmitter |
Types Head Mounted Transmitter
Din Rail Transmitter |
|
Specifications
Input : Pt-100 RTD, 2 or 3 wire / Thermocouple
Output : 2 wire 4 to 20 mA corresponding to defined input temperature range.
Operating Voltage : Nominally 24 V d.c., can range from 12 V to 36V. (For RTD only.)
Maximum Load In Loop : (Loop supply Voltage 12V) / 20mA (220 0hm for 24V d.c. supply)
Lead Wire Error for 3 Wire RTD : Less than 0.005% of span per meter of 14/36 DIN leads.
Basic Accuracy : ± 0.5% of FSD.
Change of Current 0/P with Ambient Tempreture : <± 0.01% of span per 0C Change.
Change of Current 0/P with Supply Voltage : <0.001% of span per Volt. from 12 V to 36 V.
Linearisation Ciruitry Error : <0.05% of span at any current.
Ambient Operating Temperature Range : 00C to 700C.
Indication(s) : Red LED "ON" indicates that unit is operating in loop.
Protection : Reserve polarity protected to 500 V surge suppression at 50 V d.c.
Operating Humidity Limit : 5 to 90% Non-condensing. Material of Encapsulation Epoxy. |
| |
|
| |
| Accessories for temp. Transducers |
|
| |
|
| |
| Other Product Range |
| Solid State Relay |
Proximity / Flow / Level Switches |
Humidity Sensors |
| PID Controller |
Scanner |
Data Logger with RS port output |
| Timer |
Countersl |
Humidity & Pressure Transmitters |
|
| |
|
| |
| Temperature Indicators - (Flameproof Housing) Model YOG-026/FLP |
|
|
Specifications
Input
RTD (pt-100), Thermocouples
Range
For RTD (Pt-100) - 1000C to 199.90C (Resolution 0.10C) for RTD (Pt-100) -1000C to 4000C (Resolution 10C)
For 'J' (Fe-K) 00C to 6000C
For 'K' (Cr-Al) - 00C to 12000C
For 'S' (Pt. Pt-10%Rh) 10000C to 16000C
For 'R' (Pt. Pt-13%Rh) 10000C to 16000C |
|
Indication : 3 1/2 Digit seven segment LED 1/2" & 1" size
Accuracy of Indication : ±0.5% of FSD±1 Digit.
Operating Temperature : 0C to 500C
Supply : 230VAC±10%
Flameproof Housing : As IS : 2148/2004
Degree of Protection : As per IS : 12063/1987 |
| |
|
|
Temperature Indicating Controller - (Flameproof Housing) Model YOG-062/FLP |
|
|
Specifications
Input
RTD (pt-100), Thermocouples
Range
For RTD (Pt-100) - 1000C to 199.90C (Resolution 0.10C) for RTD (Pt-100) -1000C to 4000C (Resolution 10C)
For 'J' (Fe-K) 00C to 6000C
For 'K' (Cr-Al) - 00C to 12000C
For 'S' (Pt. Pt-10%Rh) 10000C to 16000C
For 'R' (Pt. Pt-13%Rh) 10000C to 16000C
Indication : 3 1/2 Digit seven segment LED 1/2" & 1" size
Accuracy of Indication : ±0.5% of FSD±1 Digit.
Operating Temperature : 0C to 500C
Supply : 230VAC±10%
Control Accuracy : 10C or 20C nominal (Can be adjusted)
Output : Relay contact rating 5 Amps potential free
Flameproof Housing : As IS : 2148/2004
Degree of Protection : As per IS : 12063/1987 |
|
| |
|
|
Temperature Scanner - Model YOG-026/SCN |
|
|
Specifications
Input
RTD (pt-100), Thermocouples
Range
For RTD (Pt-100) - 1000C to 199.90C (Resolution 0.10C)-1000C to 4000C (Resolution 10C)
For 'J' (Fe-K) 00C to 6000C
For 'K' (Cr-Al) - 00C to 12000C
For 'S' (Pt. Pt-10%Rh) 10000C to 16000C
For 'R' (Pt. Pt-13%Rh) 10000C to 16000C |
|
Indication : 3 1/2 Digit seven segment LED 1/2" & 1" size display
Accuracy of Indication : ±0.5% of FSD±1 Digit.
Operating Temperature : 0C to 500C
Supply : 230VAC±10%
Number or Channels : 8
Channel Indication : LED with Numbers
Scan Time : 5 to 30 Sec (Adjustable)
Reset : Press switch to reset to channel number 1
Hold : To display particular channel continuously
Calibration : Individual channel calibration facility |
| |
|
|
Temperature Switch - Model YOG-062/TS |
|
|
Specifications
Input : Thermocouples 'K' (Cr-Al)
Range : 0C to 4000C
Control Accuracy : 20C nominal (Can be adjusted)
Output : Relay contact rating 5 Amps potential free
Temperature Set : Potentiometer on front panel
Accuracy : ±1% of FSD
Mounting : DIN Rail |
|
| |
|
| |
| Temperature Indicator - Model YOG-026/WM |
|
|
Specifications
Input
RTD (pt-100), Thermocouples
Range
For RTD (Pt-100) - 1000C to 199.90C (Resolution 0.10C) for RTD (Pt-100) -1000C to 4000C (Resolution 10C)
For 'J' (Fe-K) 00C to 6000C
For 'K' (Cr-Al) - 00C to 12000C
For 'S' (Pt. Pt-10%Rh) 10000C to 16000C
For 'R' (Pt. Pt-13%Rh) 10000C to 16000C |
|
Indication : 3 1/2 Digit seven segment LED 2" size
Accuracy of Indication : ±0.5% of FSD±1 Digit.
Operating Temperature : 0C to 500C
Supply : 230VAC±10% |
| |
|
|
Digital Temperature Gauges - Model YOG-026/TG |
|
|
Specifications
Input
RTD (pt-100) & Thermocouples 'K' (Cr-Al)
Range
For RTD (Pt-100) - 1000C to 199.90C (Resolution 0.10C) for RTD (Pt-100) -1000C to +4000C (Resolution 10C) For Thermocouple 'K' (Cr-Al) 0-4000C
Indication : 3 1/2 Digit seven segment LCD 1/2" size
Accuracy of Indication : ±0.5% of FSD±1 Digit.
Operating Temperature : 0C to 500C
Supply : 9V battery
Probe dia : 6.35mm, 8mm, 9.5mm
Probe length : As per your requirement |
|
| |